Product List
SNC2001 has two current inputs. As shown on Table1 INA and INB inputs are 4-20 mA current inputs. SNC2001 shows this value in 0-99,9. If there is more current than 20mA in SNC2001 inputs then Er I mistake code will show on display.
Detailed Info...
SNG2001 has two current inputs. As shown on Table1 INA and INB inputs are 4-20 mA current inputs. SNG2001 shows this value in 0-99,9. If there is more current than 20mA in SNG2001 inputs then Er I mistake code will show on display.
Detailed Info...
CSC2200 has two PT100 inputs. As shown on Table1 measurement might be done in 0-999°C range by these PT100 sensors separately for both channels. However the PT100 sensor's maximum measurement temperature is 850°C and measurement above this value would no be usefully correct. If PT100 is not plugged-in to one of the inputs of CSC2200 channel's heat is more than 999°C then Er1 mistake code will shown on display.
Detailed Info...
TSC2100 has one PT100 inputs. As shown on Table1 measurement might be done in 0-999°C range by these PT100 separately for channels.
Detailed Info...
CSG2200 has two PT100 inputs. As shown on Table1 measurement might be done in 0-999°C range by these PT100s separately for both channels. However the PT100 sensor's maximum measurement temperature is 850°C and measurement above this value would no be usefully correct. If PT100 is not plugged-in to one of the inputs of CSG2200 channel's temperature is more than 999°C then Er1 mistake code will shown on display.
Detailed Info...
TSG2100 has a PT100 inputs. As shown on Table1 measurement might be done in 0-999°C range by these PT100s separately for both channels.
Detailed Info...
GKC1201 has ONE customer-defined inputs. You can see input types in Table1.GKC1201 shows a variable (4-20mA, 0-10V, TC, PT100) between 0-999. However there is scale-setting parameter of device and display range depends on the scale. If GKC1201's one of the display values is more than 999 then Er1 mistake code will show on display.
Detailed Info...
GKC1202 has two customer-defined inputs. You can see input types in Table1.GKC1202 shows a variable (4-20mA, 0-10V, TC, PT100) between 0-999.
Detailed Info...
GGC1201 is a device with single customer determined input. Please see Table 1 for input varieties. GGC1201 shows variables at the range of 0-999. GGC1201 has scale setting in its parameters and display's range changes according to scale. If any of display's value is bigger than 999 Er1 mistake occurs in this channels display.
Detailed Info...
GGC1202 is a device with single customer determined input. Please see Table 1 for input varieties. GGC1202 shows variables at the range of 0-999. GGC1202 has scale setting in its parameters and display's range changes according to scale. If any of display's value is bigger than 999 Er1 mistake occurs in this channels display GGC1202.
Detailed Info...
Counting value could be read in range of 0-99999999 from indicator's 8-digit display by connecting one of the proximity, mechanic, or approaching switch inputs of 0-10 kHz encoders to any device. Counting value can be shown in any way with the help of multiplying and dividing ratio by connecting an encoder to input. Also it has a breakdown input which gives On-Off information.
Detailed Info...
SINGLE CHANNEL GENERAL CONTROL DEVICE
Model Code : GKC 1201
GKC1201 has ONE customer-defined inputs.